Specifications |
|||||
Insulation |
|||||
Terminal Voltage |
Range |
Max Resolution |
Accuracy |
Test Current |
Short circuit current |
125V (0% ~ +10) |
0.125~4000MΩ |
0.001MΩ |
±(2%+10) |
≤1mA |
|
250V (0% ~ +10) |
0.250~4000MΩ |
0.001MΩ |
±(2%+10) |
≤1mA |
|
500V (0% ~ +10) |
0.500~4000MΩ |
0.001MΩ |
±(2%+10) |
≤1mA |
|
1000V (0% ~ +10) |
1.000~4000MΩ |
0.001MΩ |
±(3%+10) |
≤1mA |
|
Low OHM |
|||||
Range |
Resolution |
Accuracy |
Max. open Circuit Voltage |
Overload Protection |
|
4.000Ω |
0.001Ω |
±(1.5%+30) |
5.8V |
250Vrms |
|
40.00Ω |
0.01Ω |
±(1.5%+3) |
|||
400.0Ω |
0.1Ω |
||||
Continuity Beeper |
|||||
Range |
Resolution |
Operation Resistance |
Max. open Circuit Voltage |
Overload Protection |
|
Continuity |
0.01Ω |
Resistance≤35Ω |
5.0V±1VDC |
250Vrms |
|
Short circuit current |
≥200mA |
||||
LOOP Resistance |
|||||
L-PE (Hi-Amp) |
|||||
Range (Ω) |
Max. Resolution (Ω) |
Accuracy |
|||
0.00~999 |
0.01 |
±(4% of reading+6 digits) |
|||
L-PE(No Trip): Measuring Current:15mA / Range of the Voltage Used: 195V a.c.~260V a.c.(56,60Hz) |
|||||
Range (Ω) |
Resolution (Ω) |
Accuracy |
|||
0.00~999 |
0.01 |
±(5% of reading+6 digits) |
|||
L-N: Measuring Current:2.0A / Range of the Voltage Used:195V a.c.~260V a.c.(56,60Hz) |
|||||
Range (Ω) |
Max. Resolution (Ω) |
Accuracy |
|||
0.00~999 |
0.01 |
±(4% of reading+4 digits) |
|||
RCD Testing |
|||||
Test current |
Accuracy |
||||
x1/2, x1, x2, x5 |
1.5%~ -9% |
||||
Voltage and Frequency |
|||||
Measurement Range (V)/ AC-DC |
Resolution |
Accuracy |
|||
80-500V/(45-400Hz) |
1V |
±(2% of reading+2 digits) |